THERMAL PRODUCT RESEARCH

FIRE TECHNOLOGY TO A HIGHER POWER

FIRESHELL®
Ignition Barrier Coating

Part Number: IB4

FIRESHELL® (IB4) is a proprietary, water based, 1-part, non-flammable, intumescing coating complying with AC 377 ICC ES for interior use. This coating expands up to 2000% and provides oxygen starvation when in contact with fire. This barrier coating / ignition barrier comes in both insulating and fire extinguishing versions and is a non-toxic, drain safe, no fuming, water based coating.


Applications:
  • Walls
  • Foams
  • Attics
  • Lumber

Approvals:
  • Approved Ignition Barrier over Foam
  • Complying with AC 377 APPENDIX: X
  • AQMD super compliant

Coating Coverage:
  • 175 ft2/gallon coverage


You will need a Username & Password to view our certification materials.
Please CALL: 860.767.8772

ASTM E84 Test Reports

ASTM E84 PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
E84-10 IB4 FIRESHELL®
Ignition Barrier
7 mils Standard test for surface burning characteristics of building materials Fiber cement board and select grade red oak flooring Flame:0 , Smoke:20


Miscellaneous Test Reports

MISCELLANEOUS PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
Mold Resistance IB4 FIRESHELL® NA ASTM D-3273-05 Resistance to growth of mold on the surface of interior coatings in an environmental chamber. ASTM D-3274-02 "Evaluating degree of surface disfigurement of paint film by fungal growth or soil and dirt accumulation Gypsum Wallboard No Mold Growth


ICC AC377 approved Ignition Barriers Test Reports

ICC AC377 approved Ignition Barriers PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
NFPA 286 with Acc. Criteria AC377 appendix X on SOY FOAM IB4 FIRESHELL® 8 mils Flame spread and heat release using Full Scale Room Corner over Open Cell Soy Foam 3/4# open cell soy foam (9 1/2" walls, 11 1/2" ceiling) with IB4 coating Meets NFPA 286 with Acc. Criteria AC377 appendix X
NFPA 286 with Acc. Criteria AC377 appendix X on OPEN CELL FOAM IB4 FIRESHELL® 8 mils Flame spread and heat release using Full Scale Room Corner over Open Cell Foam 1/2# open cell foam (9 1/2" walls, 11 1/2" ceiling) with IB4 coating Meets NFPA 286 with Acc. Criteria AC377 appendix X
NFPA 286 with Acc. Criteria AC377 appendix A BASELINE test NA NA NA BASELINE test: Flame spread and heat release using Full Scale Room Corner over Open Cell Foam Foam (7" walls, 11" ceiling) under 1/4" plywood room Plywood room fails at 4:29 min



TPR2 Corp. © 2011. All Rights Reserved.