| UL 263 | PART # | PRODUCT | D.F.T. | DESCRIPTION | SUBSTRATE | RESULTS |
| 1 hour wall | F1E | FIRESHELL® | 12 mils | Fire resistance testing to UL263 specifications | 1/2" gypsum wall | 1 hour rated assembly |
| 2 hour wall | F1E | FIRESHELL® | 18 mils | Fire resistance testing to UL263 specifications | 1/2" gypsum wall | 2 hour rated assembly |
| ASTM E119 | PART # | PRODUCT | D.F.T. | DESCRIPTION | SUBSTRATE | RESULTS |
| 1 hour wall | F1E | FIRESHELL® | 12 mils | Fire resistance testing to modified ASTM E119 specifications | 1/2" gypsum wall | 1 hour rated assembly |
| 2 hour wall | F1E | FIRESHELL® | 18 mils | Fire resistance testing to modified ASTM E119 specifications | 1/2" gypsum wall | 2 hour rated assembly |
| ASTM E84 | PART # | PRODUCT | D.F.T. | DESCRIPTION | SUBSTRATE | RESULTS |
| Class 'A' | F1 | Non Flammable Elastomeric Paint | Upto 15 mils | Interior/Exterior Non Flammable Paint | Cement Board | Flame:0 , Smoke:0 |
| E84-10 | IB4 | FIRESHELL® Ignition Barrier |
7 mils | Standard test for surface burning characteristics of building materials | Fiber cement board and select grade red oak flooring | Flame:0 , Smoke:20 |
| E84 | F10E | FIRESHELL® Thermal Barrier |
15 mils | Standard test for surface burning characteristics of building materials | Fiber cement board and select grade red oak flooring | Flame:5 , Smoke:20 |
| Class 'A' & extended 30 min. | F1E | FIRESHELL® ULTRA |
15 mils | Standard test for surface burning characteristics of building materials | Douglas Fir framing lumber | Class "A" 30 minute non-combustible |
| Class 'A' AQMD Paint System |
HS1 IP10 |
HeatShedder & FIRESAFE® | 7 mils 5 mils |
California Air Quality Management District - VOC Board. AQMD sponsored ASTM E84 Standard test method for surface burning characteristics of building materials | 1/2" Gypsum | Flame:5 , Smoke:5 |
| Class 'A' | IP10 | FIRESAFE® | 7 mils | Standard test for surface burning characteristics of building materials | FIRESAFE® Paint applied on cement board | Flame:0 , Smoke:0 |
| E84 | F1E | FIRESHELL® Ultra | 15 mils | Standard test for surface burning characteristics of building materials | Cement Board | Flame:0 , Smoke:0 |
| Class 'A' | PR10 | FR Polyester | NA | Standard test for surface burning characteristics of building materials | Ultra Low Petroleum Polyester | Flame:15 , Smoke:45 |
| Class 'A' | PR10 | Impregnated Polyethylene Panel | NA | Standard test for surface burning characteristics of building materials | 50% TPR2 Fire Retardant Impregnated Polyethylene Panel | Flame:5 , Smoke:5 |
| Class 'A' CDX coating System | HS1 F1E |
HeatShedder Fireshell Ultra |
8 mils 8 mils |
E84 Standard test method for surface burning characteristics of building materials | 1/2" CDX plywood | Flame:0 , Smoke:0 |
| MISCELLANEOUS | PART # | PRODUCT | D.F.T. | DESCRIPTION | SUBSTRATE | RESULTS |
| ISO 21487 and ABYC H33 Fuel tank fire & Static pressure test | F1ER | F1ER coating marine fuel tank | 18 mils | Fiberglass Fuel Tank coated with TPR2 F1ER in tumescent coating | 270 gallon Fiberglass fuel tank | Pass |
| LEED Credit Compliance | NA | Misc. | NA | Appropriate LEED's Sections for credit | NA | AQMD Super Compliant |
| EPA Method 24 - VOC test | F10E | FIRESHELL® | NA | VOC test for LEED Compliance | NA | < 1g/l |
| EPA Method 24 - VOC test | IB4 | FIRESHELL® | NA | VOC test for LEED Compliance | NA | < 1g/l |
| SFI 54.1 Thermal, Flame barrier, fire extinguishing & vapor fire resistance specification | F5E (NASCAR) F1ER (NHRA) |
TEMPROTEX™ | See Report | Multiple scenario specification: fire extinguishing, fire barrier, thermal barrier extreme duty tests for worldwide race applications | various composite, carbon fiber and plastic substrates | First approved fire extinguishing fire barrier approved for worldwide racing |
| Vapor Barrier Test | F1E | FIRESHELL® | See Report | To determine the moisture vapor transmission characteristics of a coating film | Porous Test Charts | WVT = 0.5 grains/ft2/hour WVP= 0.9perms |
| Durability Test | F4 | Non-Flammable Exterior Paint | See Report | To determine the performance properties of elastomeric high build coating | NA | Passed |
| FSIS Incidental Contact | F1E | FIRESHELL® | NA | USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" | NA | Compliant with USDA Regulations |
| FSIS Incidental Contact | F1EP | STRUCTURE SAVIOR® | NA | USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" | NA | Compliant with USDA Regulations |
| FSIS Incidental Contact | IP10 | FIRESAFE® | NA | USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" | NA | Compliant with USDA Regulations |
| FSIS Incidental Contact | F5E | TEMPROTEX™ | NA | USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" | NA | Compliant with USDA Regulations |
| FSIS Incidental Contact | F10E | FIRESHELL® | NA | USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" | NA | Compliant with USDA Regulations |
| Mold Resistance | IB4 | FIRESHELL® | NA | ASTM D-3273-05 Resistance to growth of mold on the surface of interior coatings in an environmental chamber. ASTM D-3274-02 "Evaluating degree of surface disfigurement of paint film by fungal growth or soil and dirt accumulation | Gypsum Wallboard | No Mold Growth |
| Mold Resistance | F1E | FIRESHELL® Ultra | NA | ASTM D-3273-05 Resistance to growth of mold on the surface of interior coatings in an environmental chamber. ASTM D-3274-02 "Evaluating degree of surface disfigurement of paint film by fungal growth or soil and dirt accumulation | Gypsum Wallboard | No Mold Growth |
| Mold Resistance | F10E | FIRESHELL® | NA | ASTM D-3273-05 Resistance to growth of mold on the surface of interior coatings in an environmental chamber. ASTM D-3274-02 "Evaluating degree of surface disfigurement of paint film by fungal growth or soil and dirt accumulation | Gypsum Wallboard | No Mold Growth |
| NASA STD6001 | PART # | PRODUCT | D.F.T. | DESCRIPTION | SUBSTRATE | RESULTS |
| NASA STD6001 | F1E | FIRESHELL® | NA | Flammability, odor, off gassing, and compatability requirements and test procedures for materials in environments that support combustion | Steel | Passed |
| ASTM E162 | PART # | PRODUCT | D.F.T. | DESCRIPTION | SUBSTRATE | RESULTS |
| ASTM E162 | M1 | Flexible FIRESHELL® Mastic | NA | Surface flammability of materials using radiant heat energy source | NA | Class 'A' |
| ASTM E162 | M1 | Neotard™ 9300 Nonflammable Foam | NA | Surface flammability of materials using radiant heat energy source | 3/4" fire stable foam | Class 'A' |
| ASTM E162 | M1 | Neotard™ 9300G Nonflammable Foam | NA | Surface flammability of materials using radiant heat energy source | 1/2" fire stable intumescing foam | Class 'A' |